亚欧午夜福利,香蕉在线精品视频在线,国产午夜手机精彩视频,久久亚洲AⅤ无码精品色9

網(wǎng)站導(dǎo)航
網(wǎng)站首頁  ◇  產(chǎn)品展示    ◇  通用色譜柱 ◇   GC-PLOT柱 > Rt®-Alumina BOND/CFC Columns(熔融石英plot柱)

Rt®-Alumina BOND/CFC Columns(熔融石英plot柱)

更新時(shí)間:  2017-07-05

產(chǎn)品型號(hào):  

產(chǎn)品報(bào)價(jià):  

所  在  地:  北京市朝陽區(qū)望京西園222號(hào)星源國(guó)際D座1503室

產(chǎn)品特點(diǎn):  Highly selective for C1-C5 hydrocarbons; separates all unsaturated hydrocarbon isomers above ambient temperatures.

(聯(lián)系我們,請(qǐng)說明是在 北京明尼克分析儀器設(shè)備中心 上看到的信息,謝謝?。?/div>

產(chǎn)品概述

Rt®-Alumina BOND/CFC Columns (fused silica PLOT)

 

*       Improved inertness for halogenated compounds.

*       Highly selective alumina-based column, separates most CFCs.

*       High retention and capacity for CFCs.

Product Name:

Rt-Alumina BOND/CFC

Temp. Limits:

to 200°C

Length:

30m

Internal Diameter:

0.53mm

df (µm):

10μm

 

1. Highly selective for C1-C5 hydrocarbons; separates all unsaturated hydrocarbon isomers above ambient temperatures. 2. Reactivity of aluminum oxide stationary phase is minimized so that column response for polar unsaturates, such as dienes, is optimized. Column sensitivity or response ensures a linear and quantitative chromatographic analysis for these compounds. 3. Strong bonding prevents particle generation. The column can be used in valve switching operations, without release of particles that can harm the injection and detection systems. 4. The Rt®-Alumina BOND column is stable up to 200 °C. If water is adsorbed on the column, it can be regenerated by conditioning at 200 °C. Full efficiency and selectivity will be restored. 5. High capacity and loadability give exceptionally symmetric peaks; ideal for volatile hydrocarbon separations at percent levels, as well as impurity analyses at ppm concentrations.

Guaranteed Reproducibility Each Rt®-Alumina BOND column is tested with a hydrocarbon test mix to ensure proper phase thickness and selectivity. 1,3-Butadiene is used to calculate k (capacity factor), which is a measure of phase thickness. Selectivity is measured using retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified. To measure coating efficiency, plates per meter are checked using 1,3-butadiene. Extensive testing assures reproducible retention times and predictable flow behavior column-to-column.

*       Improved inertness for halogenated compounds.

*       Highly selective alumina-based column, separates most CFCs.

*       High retention and capacity for CFCs.

The alumina adsorbent is ideal for retaining halogenated compounds, especially CFC (chlorinated flourocarbons, freons). It offers high selectivity, allowing a wide range of CFC isomers to be resolved at above ambient temperatures. The Rt®-Alumina BOND/CFC column is thoroughly deactivated to reduce the reactivity of alumina. Even though there is still some residual reactivity for some mono- or di-substituted halogenated hydrocarbons, the majority of these compounds can be accuray quantified from main stream processes or in impurity analyses.

 

 

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7
北京明尼克分析儀器設(shè)備中心

北京明尼克分析儀器設(shè)備中心

聯(lián)系人:薛海玲  電話:010-84723211  郵箱:xuehail@163.com  總部地址:北京市朝陽區(qū)望京西園222號(hào)星源國(guó)際D座1503室

研發(fā)中心:北京市平谷區(qū)中關(guān)村科技園區(qū)興谷A區(qū)平和街39號(hào)院(聯(lián)東U谷)22號(hào)樓C區(qū)

版權(quán)所有 © 2024 北京明尼克分析儀器設(shè)備中心  總流量:979666  備案號(hào):京ICP備10037012號(hào)-2

管理登陸  網(wǎng)站地圖  技術(shù)支持:化工儀器網(wǎng)